T-1/T-2
JLON
ROLL
50mm/100mm
1.2mm/1.4mm
Grade Ⅰ Grade Ⅱ
Availability: | |
---|---|
The T-1/T-2 series carbon fiber laminates(also calldcarbon fiber plates) are pultruded carbon fibre reinforced polymer (CFRP) laminates, designed for strengthening concrete, timber, masonry, steel andfibre reinforced polymer structures.
The T-1/T-2 series carbon fiber plates are bonded onto the structureas externally , bonded reinforcement using epoxy resin based adhesive for room temperatures curing.
TDS Carbon Fiber Laminates.pdf
Type | T-1 | T-2 |
Nominal Thickness | 1.2/1.4 mm | 1.2/1.4 mm |
Tensile Strength | > 2800 MPa | >2000 MPa |
Elastic Modulus | >165 GPa | >140 GPa |
Elongation at Break | >1.7% | >1.6% |
Width | 50/100 mm | 50/100 mm |
Non-corroding
▪ Very high strength
▪ Excellent durability and fatigue resistance
▪ Unlimited lengths, no joints required
▪Low system thickness, simple execution of plate intersections or crossings
▪ Easy transportation (rolls)
▪Lightweight, very easy to install, especially overhead(without temporary support)
▪Minimum preparation of plate, applicable in severallayers
▪Smooth edges without exposed fibres as result of production by pultrusion
1.Increased Load Carrying Capacity:
Increasing the load capacity of floor slabs, beams and bridge sections
▪ For the installation of heavier machinery
▪ To stabilise vibrating structures
▪ For changes in building use
2.Damage to structural elements due to:
▪ Deterioration of the original construction materials
▪ Steel reinforcement corrosion
▪ Accidents (Vehicle impact, earthquakes, fire)
3.Improvement of serviceability and durability:
▪ Reduced deflection and crack width
▪ Stress reduction in the steel reinforcement
▪ Improved fatigue resistance
4.Change of the structural system:
▪ Removal of walls and / or columns
▪ Removal of floor and wall sections to create access /openings
5.Resistance to possible events:
▪Increased resistance to earthquakes, impact or explosion etc.
6.To repair design or construction defects such as:
▪ Insufficient / inadequate reinforcement
▪ Insufficient / inadequate structural depth
A: Yes, We usually discuss with customers and help them find solutions.
A: Usually a sample will be prepared within one week after specification agreed.
A: Usually around 2-3 weeks after order confirmed. Exact delivery time depends on order quantity and Off-season/ busy season.
A: Offer TDS of each lot of production for confirmation before delivery.Once you have any quality problem, you can provide samples /pictures /test data. With our quality tracking system, we will give you feedback in short time. If the quality problem confirmed,we will send you replacement or make refund as you like.
A: Usually we do EXW, FOB, CIF, and DDU.
The T-1/T-2 series carbon fiber laminates(also calldcarbon fiber plates) are pultruded carbon fibre reinforced polymer (CFRP) laminates, designed for strengthening concrete, timber, masonry, steel andfibre reinforced polymer structures.
The T-1/T-2 series carbon fiber plates are bonded onto the structureas externally , bonded reinforcement using epoxy resin based adhesive for room temperatures curing.
TDS Carbon Fiber Laminates.pdf
Type | T-1 | T-2 |
Nominal Thickness | 1.2/1.4 mm | 1.2/1.4 mm |
Tensile Strength | > 2800 MPa | >2000 MPa |
Elastic Modulus | >165 GPa | >140 GPa |
Elongation at Break | >1.7% | >1.6% |
Width | 50/100 mm | 50/100 mm |
Non-corroding
▪ Very high strength
▪ Excellent durability and fatigue resistance
▪ Unlimited lengths, no joints required
▪Low system thickness, simple execution of plate intersections or crossings
▪ Easy transportation (rolls)
▪Lightweight, very easy to install, especially overhead(without temporary support)
▪Minimum preparation of plate, applicable in severallayers
▪Smooth edges without exposed fibres as result of production by pultrusion
1.Increased Load Carrying Capacity:
Increasing the load capacity of floor slabs, beams and bridge sections
▪ For the installation of heavier machinery
▪ To stabilise vibrating structures
▪ For changes in building use
2.Damage to structural elements due to:
▪ Deterioration of the original construction materials
▪ Steel reinforcement corrosion
▪ Accidents (Vehicle impact, earthquakes, fire)
3.Improvement of serviceability and durability:
▪ Reduced deflection and crack width
▪ Stress reduction in the steel reinforcement
▪ Improved fatigue resistance
4.Change of the structural system:
▪ Removal of walls and / or columns
▪ Removal of floor and wall sections to create access /openings
5.Resistance to possible events:
▪Increased resistance to earthquakes, impact or explosion etc.
6.To repair design or construction defects such as:
▪ Insufficient / inadequate reinforcement
▪ Insufficient / inadequate structural depth
A: Yes, We usually discuss with customers and help them find solutions.
A: Usually a sample will be prepared within one week after specification agreed.
A: Usually around 2-3 weeks after order confirmed. Exact delivery time depends on order quantity and Off-season/ busy season.
A: Offer TDS of each lot of production for confirmation before delivery.Once you have any quality problem, you can provide samples /pictures /test data. With our quality tracking system, we will give you feedback in short time. If the quality problem confirmed,we will send you replacement or make refund as you like.
A: Usually we do EXW, FOB, CIF, and DDU.