About Us        Download         Blog        Contact
banner-bg REQUEST A QUOTE

Custom Sheet Molding Compound (SMC) for Industrial Applications

Application-specific SMC formulations for electrical, automotive, infrastructure, sanitary and structural molded parts.

Match an existing SMC specification or customize the formulation for your required mechanical, electrical, flame-retardant, surface and molding performance.
SEND YOUR CURRENT TDS
banner-mobile (1)

SMC Capabilities for Application-Specific Requirements

 

Custom Formulation

 
line
 
Match an existing SMC specification or develop an application-specific formulation based on performance and molding requirements.
  

 

Glass Fiber Reinforcement

 
line
 
Glass fiber content available up to 50 wt% for selected high-strength structural SMC formulations.
  

 

Low Shrinkage

 
line
 
Low-shrink formulations available for dimensional stability and precision molding applications.
  

 

Flame Retardant

 
line
 
Selected flame-retardant SMC grades are specified for UL94 V-0 performance, subject to grade and test-condition verification.
  

 

Electrical Performance

 
line
 
Electrical-grade formulations are available for insulation performance, tracking resistance and arc resistance.
  

How to Produce Sheet Moulding Compound?

Sheet Molding Compound (SMC) is a ready-to-mold, glass-fiber-reinforced thermoset composite supplied in sheet form and processed mainly by heated compression molding.
It combines a thermosetting resin system with glass-fiber reinforcement and other formulation components to produce repeatable molded composite parts.
SMC is selected according to the finished application. Electrical insulation, outdoor components, Class-A vehicle parts and lightweight components require different balances of strength, density, shrinkage, flame behavior and surface quality.

Choose the Right SMC for Your Application

Different molded parts require different combinations of mechanical performance, electrical properties, surface quality, density and dimensional stability. Start with your application and identify the most suitable SMC reference grade.

Epoxy High-Strength SMC

 
APPLICATION POSITIONING
Epoxy / high mechanical performance
 
REFERENCE GRADE
JLONSMC1001

Weather-Resistant Outdoor SMC

 
APPLICATION POSITIONING
Weather-resistant outdoor parts
 
REFERENCE GRADE
JLONSMC2001

Electrical & Flame-Retardant SMC

 
APPLICATION POSITIONING
Electrical / flame-retardant
 
REFERENCE GRADE
JLONSMC5004

Vehicle Housing & Transportation SMC

 
APPLICATION POSITIONING
Vehicle housings / decorative parts
   
REFERENCE GRADE
JLONSMC6001

WRAS Water Tank SMC

 

APPLICATION POSITIONING

For sectional and assembled water tank panels.
   
REFERENCE GRADE
JLONSMC6006SX

High-Mechanical SMC for Local Reinforcement

 
APPLICATION POSITIONING
Local reinforcement / high-mechanical parts
 
REFERENCE GRADE
JLONSMC6006W

Class-A Low-Shrink SMC

 
APPLICATION POSITIONING
Class-A vehicle structural / large parts
 
REFERENCE GRADE
JLONSMC6008A4

Sanitary & Building SMC

 
APPLICATION POSITIONING
Sanitary / building parts
   
REFERENCE GRADE
JLONSMC8004

Low-Density Lightweight SMC

 
APPLICATION POSITIONING
Lightweight applications
 
REFERENCE GRADE
JLONSMC9009

Typical SMC Technical Data by Applicationa

Reference Grade

Application Positioning

GF

Density

Shrinkage

Key Feature

JLONSMC1001

Epoxy / high mechanical performance

45%

1.80

0.10%

Epoxy system; tensile 160 MPa; flexural 320 MPa

JLONSMC2001

Weather-resistant outdoor parts

25%

1.75

0.15%

High-weatherability grade; outdoor tactile paving

JLONSMC5004

Electrical / flame-retardant

25%

1.75

0.15%

High flame retardancy, low smoke, electrical insulation

JLONSMC6001

Vehicle housings / decorative parts

20%

1.82

0.10%

Vehicle boxes, decorative and small parts

JLONSMC6006SX

Sectional water tank panels

35%

1.78

0.10%

WRAS-certified water tank grade

JLONSMC6006W

Local reinforcement / high-mechanical parts

28%

1.75

0.10%

Local reinforcement; impact 100 kJ/m²

JLONSMC6008A4

Class-A vehicle structural / large parts

30%

1.87

0.05%

Class-A surface + low shrinkage

JLONSMC8004

Sanitary / building parts

20%

1.85

0.05%

High gloss; scratch and stain resistance

JLONSMC9009

Lightweight applications

30%

1.45

0.05%

Low-density formulation

Already Using an SMC Material? We Can Review Your Specification.

The fastest way to identify a suitable SMC starting point is to begin with your finished component and current material specification.

Send us your existing SMC TDS, material specification or molded-part drawing. JLON can compare the requirements against the available SMC reference formulations and review the formulation direction where adjustment is required.
What to Send
  • Current SMC TDS or material specification
  • Finished component and application
  • Critical target properties
  • Part dimensions or drawing
  • Existing molding conditions
  • Press information
  • Trial quantity
  • Estimated annual demand
  • Destination market
  • Required certifications

Epoxy High-Strength SMC

JLONSMC1001

JLONSMC1001 is based on an epoxy system and is positioned for applications requiring high mechanical performance. Among the supplied reference grades, it has the highest tensile strength and flexural strength values.

Property

Value

Test Method

Resin System

Epoxy system

Supplier TDS

Glass Fiber Content

45%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.10%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

160 MPa

GB/T 1447

Flexural Strength

320 MPa

GB/T 1449

Impact Strength

90 kJ/m²

GB/T 1451

Density

1.80 g/cm³

GB/T 1463

Flame Classification

V0

UL94

Best Fit
* High-mechanical-performance molded parts
* Structural components where higher tensile and flexural strength are priorities
* Projects requiring an epoxy-based SMC reference formulation

Weather-Resistant Outdoor SMC

JLONSMC2001

JLONSMC2001 is described in the supplied TDS as a high-weatherability SMC for outdoor parts. Its reference application is outdoor tactile paving.
Typical Applications
* Outdoor tactile paving
* Outdoor molded components requiring a weather-resistant SMC grade
* Infrastructure parts subject to customer environmental requirements

Property

Value

Test Method

Glass Fiber Content

25%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.15%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

70 MPa

GB/T 1447

Flexural Strength

170 MPa

GB/T 1449

Impact Strength

70 kJ/m²

GB/T 1451

Density

1.75 g/cm³

GB/T 1463

Electrical & Flame-Retardant SMC

JLONSMC5004

RXSMC5004 is a high-flame-retardant, low-smoke SMC developed for electrical insulation applications. The supplied TDS identifies subway insulated rail supports, electrical insulating parts and related electrical components as its main applications.
Why This Grade Fits Electrical Applications
* UL94 V0 flame classification is specified in the supplied TDS.
* Electrical strength is specified at >=12 kV/mm.
* Arc resistance is specified at >=180 seconds.
* Tracking resistance index is specified at >=600 V.
* Insulation resistance remains specified after water soaking.
* Water absorption is <=0.2%, supporting moisture-sensitive electrical applications.
Property Value Test Method

Glass Fiber Content

25%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.15%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

75 MPa

GB/T 1447

Flexural Strength

170 MPa

GB/T 1449

Impact Strength

70 kJ/m²

GB/T 1451

Density

1.75 g/cm³

GB/T 1463

Dielectric Loss Factor

<=0.015

GB/T 1409

Dielectric Constant

4.5

GB/T 1409

Arc Resistance

>=180 s

GB/T 1411

Electrical Strength

>=12 kV/mm

GB/T 1408

Tracking Resistance Index

>=600 V

GB/T 4207

Insulation Resistance - Normal

>=1.0 x 10^13 ohm

GB/T 31838

Insulation Resistance - After Water Soaking

>=1.0 x 10^12 ohm

GB/T 31838

Flame Classification

V0

UL94

Vehicle Housing & Transportation SMC

JLONSMC6001

JLONSMC6001 is a general vehicle-part SMC for molded housings, decorative components and other smaller vehicle accessories. It provides a balanced low-shrink formulation with 20% glass fiber content.
Typical Applications
* Vehicle housings / box-type components
* Decorative vehicle parts
* Small molded vehicle accessories

Property

Value

Test Method

Glass Fiber Content

20%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.10%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

50 MPa

GB/T 1447

Flexural Strength

120 MPa

GB/T 1449

Impact Strength

50 kJ/m²

GB/T 1451

Density

1.82 g/cm³

GB/T 1463

Flame Classification

HB

UL94

WRAS Water Tank SMC

JLONSMC6006SX

JLONSMC6006SX is designed for sectional water tank panels. The supplied TDS states that this grade has passed WRAS certification in the United Kingdom.
Typical Applications
* Sectional / assembled water tank panels

Property

Value

Test Method

Glass Fiber Content

35%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.10%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

85 MPa

GB/T 1447

Flexural Strength

200 MPa

GB/T 1449

Impact Strength

90 kJ/m²

GB/T 1451

Density

1.78 g/cm³

GB/T 1463

Certification

WRAS - stated in supplied TDS

Supplier TDS

High-Mechanical SMC for Local Reinforcement

JLONSMC6006W

JLONSMC6006W is intended for local strengthening of special parts with higher mechanical-performance requirements. Among the supplied reference grades, it provides the highest listed impact strength at 100 kJ/m² and a flexural strength of 260 MPa.

Property

Value

Test Method

Glass Fiber Content

28%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.10%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

100 MPa

GB/T 1447

Flexural Strength

260 MPa

GB/T 1449

Impact Strength

100 kJ/m²

GB/T 1451

Density

1.75 g/cm³

GB/T 1463

Typical Application Positioning
* Local reinforcement in components requiring higher mechanical performance
* Special molded parts where strength or impact performance is locally critical

Class-A Low-Shrink SMC

JLONSMC6008A4

JLONSMC6008A4 is positioned for vehicle structural parts and large components requiring Class-A surface quality together with low shrinkage. Its measured shrinkage is 0.05%.
Typical Applications
* Vehicle structural components
* Large vehicle parts
* Visible molded parts requiring low shrinkage and Class-A surface positioning

Property

Value

Test Method

Glass Fiber Content

30%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.05%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

75 MPa

GB/T 1447

Flexural Strength

180 MPa

GB/T 1449

Impact Strength

75 kJ/m²

GB/T 1451

Density

1.87 g/cm³

GB/T 1463

Surface Positioning

Class-A surface quality

Supplier TDS

Sanitary & Building SMC

JLONSMC8004

JLONSMC8004 is developed for sanitary washbasins and shower-tray bases. The supplied TDS describes the grade as high-gloss, low-shrink, scratch-resistant and stain-resistant, making it suitable as a base material for higher-end sanitary applications.
Typical Applications
* Sanitary washbasins
* Shower-tray bases
* Other molded sanitary or building products requiring low shrinkage and high surface quality
Property Value

Test Method

Glass Fiber Content

20%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.05%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

45 MPa

GB/T 1447

Flexural Strength

120 MPa

GB/T 1449

Impact Strength

50 kJ/m²

GB/T 1451

Density

1.85 g/cm³

GB/T 1463

Surface Features

High gloss; good scratch and stain resistance

Supplier TDS

Low-Density Lightweight SMC

JLONSMC9009

JLONSMC9009 is a low-density SMC for lightweight applications. Its density is 1.45 g/cm³, the lowest value among the supplied reference grades.
 
Typical Applications
* Lightweight molded components
* Applications where lower density is a key material-selection requirement

Property

Value

Test Method

Glass Fiber Content

30%

GB/T 15568

Heat Deflection Temperature

>=200°C

GB/T 1634

Shrinkage

0.05%

GB/T 15568

Water Absorption

<=0.2%

GB/T 1462

Tensile Strength

50 MPa

GB/T 1447

Flexural Strength

130 MPa

GB/T 1449

Impact Strength

70 kJ/m²

GB/T 1451

Density

1.45 g/cm³

GB/T 1463

SMC Compression Molding Guide

SMC is mainly processed by heated compression molding. The following values provide a starting process reference based on the supplied TDS information. Actual molding conditions should be adjusted according to the formulation, part geometry, mold and press.

Process: SMC Charge Preparation → Charge Placement → Mold Closing → Compression & Curing → Demolding → Finishing & Inspection

Parameter

Reference

Compression Time

Approximately 1 minute per 1 mm of finished-part thickness

Upper Mold Temperature

146–150°C

Lower Mold Temperature

138–142°C

Press Force Reference

Approximately 1000 tons/m² of projected area

Engineering Note: The 1000 tons/m² value is a factory process reference for press-force estimation, not a universal material property. Final press selection should be checked against actual projected area, geometry and flow requirements.

SMC Storage, Packaging & Shelf Life

Item

Reference Requirement

Packaging

Aluminized film, sealed to reduce air permeability

Storage Temperature

Below 25°C

Environment

Dry, ventilated indoor storage

Sunlight

Avoid direct sunlight

Packaging Condition

Keep package sealed

Shelf Life

3 month from production date under specified conditions

Safety

Read the product SDS before use

Why Choose JLON for Sheet Molding Compound?

 

Application-Based Grade Selection

 
line
 
We start from the molded component and target performance instead of pushing one generic SMC grade for every application.
     

 

Custom Requirement Review

 
line
 
If a standard reference formulation does not match your project requirements, send your current TDS or target specification for review.
  

 

Technical Data First

 
line
 
Compare glass-fiber content, shrinkage, water absorption, mechanical performance, density and application-specific properties before starting a molding trial.
  

 

Molding Support

 
line
 
Material selection can be reviewed together with mold temperature, compression time, press capacity, projected area and molding conditions.
  

 

Multiple Reference Formulations

 
line
 
Our current SMC portfolio covers electrical, high-strength, weather-resistant, vehicle, water tank, reinforcement, Class-A, sanitary and lightweight applications. 

Supply & Customization

Standard SMC sheet width is 1 meter, with typical package weights of 800–1,200 kg. Colors can be customized according to project requirements. MOQ and trial quantities are evaluated based on the specific order and application. Standard lead time is approximately 2–4 weeks.
Custom development lead time, supply capacity and quality system/certification information are intentionally not presented on this landing page.

Item

Reference Requirement

Standard Sheet Width

1 meter

Package Weight

800–1,200 kg

Available Colors

Custom colors available

MOQ

Based on actual order requirements

Trial Quantity

Based on project requirements

Standard Lead Time

2–4 weeks

From Material Selection to Molding Support

Use real JLON images only: SMC production, laboratory/testing, SMC sheet/roll, quality inspection, compression molding trial and finished components. Do not publish supplier logos or confidential customer product photos.

Frequently Asked Questions About Sheet Molding Compound

  • Q What is Sheet Molding Compound (SMC)?

    A Sheet Molding Compound is a ready-to-mold, glass-fiber-reinforced thermoset composite supplied in sheet form and processed mainly by heated compression molding.
  • Q Is Sheet Moulding Compound the same as Sheet Molding Compound?

    A Yes. “Sheet Molding Compound” is the American English spelling, while “Sheet Moulding Compound” is the British / European spelling. Both are commonly abbreviated as SMC.
  • Q How do I choose an SMC grade?

    A Start with the finished component, application, required performance and molding conditions. JLON can compare these requirements with the available application-specific SMC reference formulations.
  • Q Can SMC achieve UL94 V-0?

    A Selected reference grades are specified as UL94 V-0 in the supplied TDS information. The applicable test thickness should be confirmed from the underlying test report before publication or project approval.
  • Q Which SMC grade is suitable for electrical insulation?

    A JLONSMC5004 is the current electrical reference grade. Its supplied data includes electrical strength of ≥12 kV/mm, arc resistance of ≥180 seconds and tracking resistance index of ≥600 V.
  • Q Which SMC grade has the highest mechanical strength?

    A JLONSMC1001 has the highest listed tensile strength at 160 MPa and flexural strength at 320 MPa among the supplied reference grades. JLONSMC6006W has the highest listed impact strength at 100 kJ/m².
  • Q Is there a low-density SMC for lightweight applications?

    A Yes. JLONSMC9009 has a listed density of 1.45 g/cm³ and is positioned for lightweight applications.
  • Q Which SMC is suitable for Class-A vehicle surfaces?

    A JLONSMC6008A4 is positioned for vehicle structural and large parts requiring Class-A surface quality. Its listed shrinkage is 0.05%.
  • Q Can SMC be used for sectional water tanks?

    A Yes. JLONSMC6006SX is designed for sectional water tank panels, and the supplied TDS states that the grade has passed WRAS certification.
  • Q What are the typical SMC compression-molding conditions?

    A The supplied TDS information gives a starting reference of approximately 1 minute per 1 mm of finished-part thickness, an upper mold temperature of 146–150°C, a lower mold temperature of 138–142°C and a press-force reference of approximately 1000 tons/m² of projected area. Final conditions should be adjusted to the actual part and process.
  • Q How can I get a suitable SMC material recommendation?

    A Send your current SMC TDS, target specification, molded-part drawing or application requirements. JLON can review the requirements and recommend an appropriate starting grade or formulation direction.

Need a Custom SMC Recommendation?

Tell us what you are molding and what the material needs to achieve.
Send your current SMC TDS, target specification or molded-part drawing. We will review the application and recommend an appropriate SMC starting grade or formulation direction.
Get In Touch
+8619306129712
NO.2-608 FUHANYUAN,TAIHU RD, CHANGZHOU,JIANGSU ,CHINA
Products
Application
Quick Links